MTCA.4 Load Testing and Monitoring with Display, AMC

  • Up to 192W adjustable power load
  • True payload power request to the carrier (MCH/Shelf)
  • Front panel LCD to indicate status
  • Eight temp sensors to monitor various on-board temperatures
  • RISC processor
  • IPMI 2.0 compliant
  • RoHS compliant

Download Datasheet Add to Info Request

add to compare

The AMC011 provides an easy way to test/monitor AMC slots under different power loading conditions. The module includes two front panel switches for configuration. The rotary switch is read during power up by the on-board IPMI controller, which uses the setting to request the specified amount of power needed during test and verification from the carrier (MCH/Shelf). A second switch is used to increase or decrease the actual power consumption of the board at any time during the test.

An LCD display on the front panel allow for effortless monitoring of the power being used. There is a temperature sensor on the air flow intake side and others at the air flow exit side to continually monitor the air temperature. A push button allows the user to scroll the display output.

The module has a serial port in the front that allows a more dynamic configuration of the load using predefined profiles selected from a menu driven interface.

Key Features
  • Up to 192W adjustable power load
  • True payload power request to the carrier (MCH/Shelf)
  • Front panel LCD to indicate status
  • Eight temp sensors to monitor various on-board temperatures
  • RISC processor
  • IPMI 2.0 compliant
  • RoHS compliant
Benefits
  • LCD Display for easy monitoring
  • Design utilizes proven VadaTechsubcomponents and engineering techniques
  • Electrical, mechanical, software, and system level expertise in house
Specifications
Specifications

Block diagram

Related Products

AMC001

AMC Load Module

  • Single module, mid size or full size
  • 32-bit IPMI RISC processor
  • Up to 90W adjustable power load
  • True payload power request to the carrier (MCH/Shelf)
  • Front panel LED to indicate status and power consumption
  • Six temp sensors to monitor various on-board temperatures
  • All differential pairs routed for ease of access (loop back using zero ohms resistors)
  • IPMI 2.0 compliant
  • RoHS compliant
View product AMC001 Data Sheet

AMC012

MTCA.4 Five-zone Airflow Meter with Display, AMC

  • Five zone airflow sensor
  • Eight temp sensors to monitor various on-board temperatures
  • Module allows adding blocks to emulate a truepay load module impedance
  • Front panel LCD to indicate airflow and temperature
  • RISC processor
  • IPMI 2.0 compliant
  • RoHS compliant
View product AMC012 Data Sheet

MRT011

MTCA.4 RTM Load Testing

  • Up to 160W adjustable power load
  • True payload power request to the carrier (MCH/Shelf)
  • Eight temp sensors to monitor various on-board temperatures
  • IPMI 2.0 compliant
  • RoHS compliant
View product MRT011 Data Sheet

Info request

Create a list of products to inquire about for more information or quote request.